Alsanie Logo
Scientific / 3B

Aurora the Respiratory Training Simulator dark skin manikin

Product Overview

Discover the Aurora manikin a cost effective choice for enhanced respiratory and ventilation training scenarios. This advanced medical simulator is designed to strengthen critical skills in decision making team coordination and patient care with a particular focus on respiratory management ventilator use and Advanced Life Support (ALS) techniques. Its capability to provide detailed patient condition assessments and simulate a wide array of clinical situations makes Aurora an essential tool for professionals in Respiratory Therapy Emergency Medical Services (EMS) Emergency Nursing ICU/Critical Care and Physicians. ? Advanced Internal Simulated Lung Technology Aurora takes medical simulation to new heights with its Internal Simulated Lung (ISL) which is based on the world renowned ASL 5000? Breathing Simulator technology. This technology ensures a deeply immersive hands on training experience featuring a tetherless system to facilitate lifelike ventilator interactions ideal for training healthcare professionals. Aurora is compatible with nearly any mode of ventilation it accurately simulates respiratory mechanics maintains therapeutic PEEP levels and breathes spontaneously while being ventilated to prepare healthcare professionals for a wide range of ventilation scenarios.? ? Real Time Feedback for BVM Ventilation Training Aurora is designed to teach and enhance bag valve mask (BVM) ventilation skills for healthcare professionals. ?Users can practice and perfect their BVM techniques under various clinical scenarios while receiving real time feedback ?on critical factors such as volume pressure and rate of delivered breaths. ?Aurora?s advanced sensors and feedback systems allow for the recreation of different complexities encountered in real respiratory emergencies to provide learners with a realistic and challenging training environment. Mastering Non Invasive Ventilation Techniques Aurora allows learners to also gain hands on experience with non invasive ventilation strategies including the management of various respiratory conditions using CPAP and BiPAP systems. Aurora ensures that medical professionals build the competence and confidence to utilize non invasive ventilation techniques effectively and safely in clinical settings. Realistic Critical Care Ventilation Training The Aurora manikin serves as a vital resource for critical care and ICU training providing an authentic experience with ventilator settings alarms and patient reactions. It responds accurately to a multitude of patient conditions and disease states such as Asthma COPD ARDS and emphysema. Additionally it simulates patients with spontaneous breathing during ventilation covering the entire spectrum from those with weak breathing efforts to those ready for extubation making it an indispensable tool for bridging the gap between theoretical knowledge and hands on clinical practice. Key Training Features of the Aurora Manikin: Highly realistic ventilation training at an affordable cost Compatible with your own real equipment including bag valve mask non invasive ventilation (CPAP/BiPAP) and ICU ventilators Ideal for team training due to comprehensive patient assessment capabilities Provides dynamic feedback through chest movements imaging like x rays and CT scans realistic sounds and a lifelike Patient Monitor interface Facilitates patient transport scenarios with its wireless capabilities Includes a Debriefing environment with objective simulation data as well as real time feedback for BVM ventilation and CPR Features user friendly software for intuitive patient simulation management and custom scenario creation Aurora?s key simulation capabilities underscore its role as an invaluable asset in medical education particularly for those specializing in respiratory therapy and critical care. Detailed Technical Specifications Advanced Respiratory Mechanics: Aurora offers intricate respiratory simulations with adjustable parameters for resistance compliance and breath rate along with a high maximum tidal volume and the ability to hold substantial PEEP. Unique features include: Resistance ? 3 to 150 cmH20/L/s Compliance ? 3 to 150 mL/cmH20 Breath rate ? passive to 100 bpm Patient effort (muscle pressure) ? 0 to 50 cmH20 Neural inspiratory time ? 0.1 to 3.6 seconds Tidal volume ? Maximum 900 mL Holds PEEP > 20 cmH20 Simulate tracheal as well as left and right bronchial resistance Simulate independent inspiratory and expiratory resistance Simulate independent left and right lung compliance Control patient?s work of breathing with variable patient effort Spontaneous breathing recognized by a real mechanical ventilator Virtual Ventilator software included for fully software based simulations Intuitive Simulation Control Control features include: Pre built lung models and scenarios provided by IngMar Medical Save custom lung models and scenarios Simulate a cough breath during simulation with one click Randomize all lung parameters within a set boundary Trend each lung parameter individually Vary lung parameters during scenario with immediate impact on ventilator waveforms Change ventilation modes (e.g. volume to pressure control) seamlessly on the same patient without adjusting patient settings or interrupting the simulation Comprehensive Patient Assessment and Psychomotor Skills Training The Aurora manikin accommodates adult and pediatric (12 years and older) patient simulations featuring: Anatomically realistic chest movement Unilateral and bilateral chest movement Anatomically correct airway allows for realistic oral and nasal intubation using OPA NPA iGel LMA LT and ETT Vascular access (IV/IO) Head tilt and chin lift CPR with real time feedback Bag valve mask training with real time feedback Gastric insufflation Esophageal intubation Tetherless capability (runs without wall power for at least 2 hours) Connect software wirelessly Realistic durable skin True to life Patient Monitor provides learner with assessments during simulation Library of EKG and CO2 waveforms 12 lead ECG display Heart lung and bowel sound auscultation Versatile Ventilation Scenario Applications: Autora interacts realistically with all modes of ventilation including Pressure/Volume Control and spontaneous modes such as Pressure Support ASV and PAV Interacts realistically with Bag valve Mask (BVM) and Non invasive Ventilation (NIV) Simulate any type of patient ventilator dyssynchrony scenario (inspiratory expiratory trigger and cycle) Simulate spontaneous breathing trial or patient weaning scenarios Delivery Content Aurora manikin containing advanced respiratory and lung technology Windows based tablet with pre installed RespiSim? Software Window based tablet with pre installed RespiSim? Patient Monitor application Manikin charger Manikin consumables package including tape lubricant IV cannulation pad forearm IV cannulation pad dorsal humeral IO replacement and humeral IO extra fat User Manual

Model / SKU: N/A

Price: Contact for Quote
Download Brochure (PDF)

Key Specifications

No key specifications listed.

Technical Specifications

Detailed technical data not currently available.

Support & Downloads

No additional manuals or support files listed.